Previous Page  35 / 116 Next Page
Information
Show Menu
Previous Page 35 / 116 Next Page
Page Background

PLUMBING CONNECTION

SUMMER 2015 35

performance based outcome led to

the engagement of HWU, who are

acknowledged as a world leader in

drainage research,” Brad explains.

“They were keen to be involved in a

“live” project and understood the basic

matter at hand – water conservation

impacting on the carrying capacity

of drainage. HWU developed flow and

time profiles for all fixtures and fittings

and loaded this information into their

Drain Net software simulation model

developed specifically for the project.

HWU used statistical/probability

numerical simulation over a three

hour window of 0600 to 0900, where

every fixture and fitting in all of the

apartments was used, deriving a

maximum flow rate in the drainage

network adequate for the installation

of a 150mm diameter drain rather than

a 225mm diameter drain as prescribed

by the relevant Australian Standards.

As you can imagine, the fixture and

fitting manufacturer would also have

to back up their products’ claims

and have the ability to prove that

their products could stand up to the

kind of treatment being asked of the

alternative solution.

“The local authorities required

a written warranty from Studor to

state that the performance based

outcome would have no detrimental

effect on their air admittance valves

and positive air pressure attenuators

installed within the sanitary plumbing

system and that Studor were willing

to warrant their products within this

project. Mr Steven White from Studor

was also consulted and was a key

stakeholder. He had no hesitation in

providing the warranties given that

HWU were involved in the verification

of the outcome,” Brad says.

Sellick Consultants informed ABCB

of its proposal to which they advised

Sellick that the matter was something

the local regulator had to consider

but they would be interested in

understanding our proposal and the

outcome. It is important to remember

that the ABCB is merely a facilitator

and not the regulator.

“We did pass on our final engineering

brief to them for their information and

this included the paper prepared by

HWU to validate our claims.”

Sellick Consultants has been

granted an Australian Innovation

Patent by the Australian patent office.

The patent takes into account the

impact of WELS ratings of fixtures and

fittings and adjusts drainage/water

loadings accordingly to suit the water

conservation measures adopted