Previous Page  57 / 84 Next Page
Information
Show Menu
Previous Page 57 / 84 Next Page
Page Background www.plumbingconnection.com.au

5 7

filtered out, with almost all resulting UV that reaches the

Earth’s surface consisting of about 95% UV-A and 5% UV-B.

No measurable amount of UV-C is observed on earth

originating from the sun. Instead, all sources of UV-C occur

from manmade processes. The effectiveness of UV-C

disinfection depends on the total energy applied to the

microbiological threat, a result of distance from the UV-C

source and exposure time.

UV-C air sterilisation is a growing use of UV-C, but requires

careful calculation to maintain efficacy as air flow and volume

affect exposure time. SteriWhite Air Air Q, which is European

University-tested to 99.99% efficacy, meets local certification

requirements and codes in Australia.

UV-C lamps emit a bluish light; this is not UV light, but a

result of the mercury used which also emits light at the low

end of the visible light spectrum. Most UV lamps typically have

a lifespan of 8–10,000 hours. SteriWhite Air’s 16,000-hour

lamp life means that an industry leading sterilisation period

exists without the need for ongoing maintenance and lamp

replacements.

The SteriWhite Air UVC air sterilisation device does not

require filter changes and has few moving parts, resulting in

minimal downtime for ongoing service and maintenance.

HUMAN SAFETY

Care is required in design to minimise ‘leakage’ of UV-C, as

it is hazardous to humans. ESW has further modified the

already robust SteriWhite Air to ensure there is no observable

quantity of UV-C leakage, even under rigorous Australian

independent testing. Hazards of UV-C often mean servicing

and maintenance, including lamp changes that must be

conducted by a trained technician. SteriWhite Air lamps are

safe and can easily be changed by anyone following the proper

instructions.

UV-C sterilisation does not require handling, transportation,

or storage of hazardous or corrosive chemicals, nor does it

leave or create chemical residue.

UV-C sterilisation can be much more sustainable than other

air-treatment methods due to low parts turnover, lack of

chemical use and low power consumption.

The UV lamps via the inbuilt timer can operate for a typical

eight-hour workday duration and for five days a week,

providing a potential lamp life of up to 10 years. If a 24/7 lamp

operation is necessary, the life of the lamps can be around two

years.

FAQS

Q: Do I have to vacate the room while the air is being

disinfected?

A: No. The SteriWhite Air Air Q was developed specifically for

use in occupied rooms. Testing conducted to the highest

Australian standards by independent labs confirmed the

device does not leak observable quantities of UV-C light and

can be operated 24/7 in occupied spaces safely.

The unit produces neither ozone nor other harmful

substances and is designed with safe housing and is free of

chemicals.